Sensor Logic¶
In iqMAXREFDES42 have been implemented simple switch-point hysteresis logic and additionally can be configured as normally open (NO) or normally closed (NC).
By default ambient temperature switch-point settings (32767 is the maximal value):
What | SP (Level) | Hysteresis | Mode |
---|---|---|---|
Ambient temperature | 9148 (0x23BC, 30°C/86°F) | 32 (0x20, 1°C/1.8°F) | Normally Open (NO) |
Note
Ambient temperature switch-point flag always indicated on digital output channel (red LED).